NIST IR Spectral Emittance Lab

The Optical Properties measurements laboratory at The USA National Institute of Standards & Technology (NIST), a part of the Optical Technology Division of the PHYSICS Laboratory has been developing a full spectral emissivity (emittance) measurement capability.

This facility enables the measurement of spectral emittance using the direct method of radiance comparison of the sample with a blackbody reference source. Spectral emissivity is a key physical property in the determination of radiation transfer and balance.

Numerous industrial and scientific applications, such as remote sensing and single- and multi-band pyrometry, require its accurate determination.

emittance_fig

Layout of the NIST Setup for Direct and Indirect Infrared Spectral Emittance Measurements


The sample emittance is determined through a series of measurement steps. The first step is a measurement of the sample’s hemispherical-directional reflectance at the measurement temperature and at a single wavelength matched to the filter radiometer. A diode laser or broadband source input to the integrating sphere, is selected based on the temperature and rough emittance value of the sample. The reflectance is obtained via comparison to a calibrated standard.

The second step is a relative radiance measurement of the sample to a blackbody at the same wavelength. The integrating sphere is removed for the second step. The temperature is then calculated from the results of these two steps. This procedure has the benefit of obtaining the temperature of the sample from the region on the sample identical to that for which the infrared spectral emittance is measured. It also makes use of the steep short wavelength edge of the Planck function for sensitive (and higher accuracy) temperature measurement.

Finally, the Fourier transform infrared spectrometer is used to compare the sample spectral radiance to that of the reference blackbody source as a ratio, and the sample emittance is obtained from the ratio and Planck’s Law using the sample and blackbody temperatures.

Alternatively, spectral directional emittance can be determined indirectly from reflectance and transmittance measurements described in Infrared Spectrophotometry. These capabilities have limits of temperature, measurement geometry and sample type.
Specifications / Capabilities:

The facility consists of a set of reference blackbody sources mounted on a motorized stage for selection; interchangeable sample heater/mounts on motorized translation and rotation stages; a removable visible/near-infrared integrating sphere for measuring the sample temperature above 500 K; low scatter interface optics to image the 3 mm to 5 mm central region of the sample or blackbody source onto a water cooled field stop; the field stop is re-imaged onto either a Fourier transform spectrophotometer equipped with beamsplitters and detectors to cover a spectral range from the visible through the far infrared or a set of filter radiometers mounted on a motorized translation stage for temperature scale transfer between the blackbody sources and for sample temperature determination (together with the integrating sphere); a sectored purge enclosure for the entire beam path; electrical supply, signal, purge gas (Ar, or N2), and cooling water subsystems; control of system elements and data processing via several PC computers using LabView software programs.

Each blackbody contains calibrated platinum resistance thermometer (PRT) or thermocouple (TC) temperature sensors. These are used to control and monitor changes in the blackbody temperature. For absolute temperature determination, two fixed point BB furnaces with interchangeable crucibles (containing Ag, Al, Zn, Sn and In) are used.

Filter radiometers (with filters at 650 nm, 900 nm, 1550 nm, and 2400 nm) are used to transfer the scale from the fixed points to 4 variable temperature blackbody’s covering a temperature range of 250 K to 1400 K. The spectral emissivities of the blackbodies have been calculated using a Monte Carlo ray tracing algorithm with input of the measured spectral reflectance of the cavity wall materials or coatings.

Associated Programs/Projects:



Infrared optical properties of materials and components
Fourier transform infrared spectrometer (FTIS) facility

Selected Publications

Infrared Spectral Emissivity Characterization Facility at NIST, L.M. Hanssen, S.N. Mekhontsev, and V.B. Khromchenko,Proc. SPIE 5405, 112 (2004).

Temperature-Resolved Infrared Spectral Normal Emissivity of SiC and Pt-10Rh for Temperatures up to 900 C

Use of a High Temperature Integrating Sphere Reflectometer for Surface Temperature Measurements, L.M. Hanssen, M. Noorma, A.V. Prokhorov, S.N. Mekhontsev, and C.P. Cagran, Intl. J. Thermophysical Prop.

2 comments:

Bruce Dover said...

Hi. I have a need for spectral emissivity of some typical refractories. The application is somewhat unique, high temperature source / moderate temperature operation.
I have found data for alumina and am now searching for mullite and SiC.
I think I found SiC here but it's not obvious (to me, yet) which of the graphs on the .../sesl/nist-ir-spectral-emittance-lab page to use.

My phone number is 716 684 7400 X 1172
Thanks
Bruce Dover, Harper International

raymundo said...

We do have some data on Mullite (a mixture of Silica & Alumina) and more on SiC. We'll see about getting it added during the week of March 14th. A lot depends upon the surface roughness and the waveband of interest. Since neither of these changes surface properties greatly with moderate variations in temperature, there should be some literature values to guide you.

Increasing the accuracy of your temperature measurements.

Monitor Newsletter at Windmill Software ( https://www.windmill.co.uk/ ) regularly publishes useful articles related to measurement, control,...