Measurements of Pool-Fire Temperature Using IR Technique. (419 K)

By Qian, C.; Saito, K.

Ref: Combustion Institute/Central and Western States (USA) and Combustion Institute/Mexican National Section and American Flame Research Committee. Combustion Fundamentals and Applications. Joint Technical Meeting. Proceedings. April 23-26, 1995, San Antonio, TX, Gore, J. P., Editor(s), 81-86 pp, 1995.

Sponsor: National Institute of Standards and Technology, Gaithersburg, MD

Abstract:
We made an attempt to measure the flame temperature of four different diameter hexane-pool-fires using IR technique. Emissivities for these four flames were estimated based on measurements of transmitted energy from a blackbody radiant source. The average flame temperature half way to the flame tip was 700-800 deg C, which was in good agreement with thermocouple-temperature measurements by others for a 3 m diameter hexane pool fire.

Click here to download a pdf version of the report:Measurements of Pool-Fire Temperature Using IR Technique. (419 K)