Showing posts with label Semiconductors. Show all posts
Showing posts with label Semiconductors. Show all posts

Friday, May 8, 2009

Table of Emissivities in Three Popular Spectral Regions

The Table of Emissivity on the INFRAPOINT Messtechnik GmbH website, posted in 2009 (No longer available online) had summary data for a wide variety of materials broken down into three distinct spectral regions for the wavelength regions where the majority of infrared radiation thermometers and Infrared Thermal Imaging cameras operate.

First and second are tables that deal with the narrow spectral bands about 0.9 µm and 1.6 µm, the regions where many Silicon (Si) photovoltaic detectors (peak wavelength response: (0.9 µm) and both Germanium (Ge) and Indium Gallium Arsenide (InGaAs) (nominal wavelength region (0.7 - 1.6 µm) are used.

The third table cover the 8 - 14 µm waveband where most "low" (near ambient) temperature IR thermometers and thermal imaging sensors operate.

It has been reproduced here below in the spirit of Internet openness from our archives. We hope there is no problem in doing so and if any heir or assigns of INFRAPOINT Messtechnik GmbH wishes to keep this information secret, obviously against the original intent of INFRAPOINT, please contact us according to our webpage contact information.






























































































































































































































































































  Table of emissivity    
 The emissivity ? (radiant emittance factor) is the relationship of the radiated intensity of a body to the intensity of a blackbody of the same temperature.
It is the most important factor, in order to determine of an item exactly.


If you want to measure the surface temperature with an infrared thermometer the emissivity must be known and correct adjusted
on the instrument.
        
  Material Emissivity   Material Emissivity 
 MetalsWavelength
0.9 µm 
Wavelength
1.6 µm 
 Non metalsWavelength
8 - 14 µm  
 
        
 Aluminium, bright0.05 - 0.25 0.05 - 0.25  Asphalt 0.95  
 Aluminium, anodized0.2 - 0.4 0.1 - 0.4  Concrete0.95 
 Chrom, bright0.28 - 0.32 0.25 - 0.3  Gypsum0.85 - 0.95  
 Iron, oxidised0.4 - 0.80.5 - 0.9  Graphite 0.75 - 0.92  
 Iron, not oxidised0.350.1 - 0.3  Glass*, pane 0.80  
 Gold, bright0.020.02  Rubber0.85 - 0.95  
 Copper, bright0.06 - 0.200.06 - 0.20  Wood, natural0.8 - 0.95  
 Copper, oxidised 0.5 - 0.8 0.7 - 0.85  Chalk0.98  
 Magnesium0.03 - 0.8 0.05 - 0.3  Ceramics0.85 - 0.95  
 Brass, bright 0.8 - 0.95 0.01 - 0.05  Plastics0.85 - 0.95  
 Brass, oxidised 0.65 - 0.75 0.65 - 0.75  Masonry0.85 - 0.95  
 Nickel, oxidised 0.8 - 0.9 0.4 - 0.7  Human skin0.98  
 Platinum, black - 0,95  Oil paints0.85 - 0.95  
 Silver 0.02 0.02  Paper 0.85 - 0.95  
 Steel, melted0.30 0.20 - 0.25  Porcelain0.85 - 0.95  
 Steel, oxidised 0.8 - 0.9 0.8 - 0.9  Quartz 0.8  
 Steel, bright0.40 - 0.45 0.30 - 0.4  Carbon black0.95  
 Titanium, bright0.5 - 0.75 0.3 - 0.5  Chamotte 0.85 - 0.95  
 Titanium, oxidised - 0.6 - 0.8  Textile, Drapery0.85 - 0.95  
 Zinc, bright0.6 0.4 - 0.6  Tone0.95  
 Zinc, oxidised 0.5 0.05  Water0.95 
 Tin0.25 0.1 - 0.3  Cement 0.9  








* The emissivity of glass (0.95 - 0.97 µm) is in the range of 4.5 - 7 µm particularly high.
Glass has there an absorption band (spectral range, where materials absorb radiation).
To measure glass surface temperatures, the best wavelength is at 5.14 µm, because
the measurement at this range is not affected by absorption bands such as carbon or hydrogen.

Friday, December 26, 2008

Handbook of OSML Libraries: Emittance

CRMHT - CNRS Centre de Recherche sur les Matériaux à Haute Température, Orléans, France
Mesure indirecte de l'émittance (Includes sample data for Silicon Dioxide)

Mesure de la réflectivité et de la transmissivité normales spectrales (10 à 40 000 cm-1 soit 1 000 à 0,25 µm).

L'émissivité normale spectrale se déduit indirectement par calcul de ces deux grandeurs par application des lois de Kirchhoff ,

i.e. at each wavelength, Emissivity =1 - Reflectivity - Transmissity






Emittance-WNHandbook of OSML Libraries














E - dielectric function
N - complex refractive index
RT - reflectivity, layer transmissivity
WN - wave number
OSML Source : [Emitttance-WN]
Function Group : [Optical Functions]







Emittance-E






Emittance-E (AE) represents the fraction of the incident radiation that is absorbed (Kirchhoff law) by a sample with a plate shape. Its expression take into account for multiple reflections (no interference effects) and depends on the dielectric functions of the incident medium Ei, those of the material Eo and the thickness d of the sample.
Function signature : Emittance-E(x,Ei,Eo,Thickness)Units


The spectral dependence must be expressed in wave numbers (cm-1) and the thickness in (cm).







Emittance-N







Emittance-N (AN) represents the fraction of the incident radiation that is absorbed (Kirchhoff law) by a sample with a plate shape. Its expression take into account for multiple reflections (no interference effects) and depends on the complex refractive indexes of the incident medium Ni, those of the material No and the thickness d of the sample.
Function signature : Emittance-N(x,Ni,No,Thickness)Units


The spectral dependence must be expressed in wave numbers (cm-1) and the thickness in (cm).







Emittance-RT







Emittance-RT (ART) represents the fraction of the incident radiation that is absorbed (Kirchhoff law) by a sample with a plate shape. Its expression take into account for multiple reflections (no interference effects and depends on the reflectivity R and the layer transmissivity T of the sample.
Function signature : Emittance-RT(R,T)







Planck-WN







Planck-WN (PWN) is the wave number version of the Planck function. Its expression depends on the temperature T.
Function signature : Planck-WN(x,T)
Constants : C1=1.1910 10-6 (W.m2) C2=1.4388 (cm.K)











See Also : [Optical Functions] [Reflectance-WN] [Transmittance-WN]


Handbook of OSML Libraries

Friday, March 21, 2008

ET10 Reflectometer Measures Emissivity

San Diego CA, USA --Surface Optics' ET10 measures emissivity values in two most commonly used spectral regions, 3 to 5 and 8 to 12 microns.

Its main application is to produce emissivity values for the infrared cameras.

Advanced IR cameras require the input of an emissivity value for accurate temperature calculations. The emissivity values obtained from tables can be far from real leading to large temperature uncertainties.

The ET10 can be used in the lab or in the field and on small or large objects. With the ET10 one can measure emissivity of any surface in just a few seconds.

Monday, January 7, 2008

Polarized spectral emittance from periodic micromachined surfaces. II. Doped silicon: Angular variation

PJ Hesketh, JN Zemel, B Gebhart - Physical Review B, 1988 - APS Polarized spectral emittance from periodic micromachined surfaces. II. VOLUME 37, NUMBER 18

From the Abstract:The polarized directional spectral (3 um <=lambda =>14um) emittances (PDSE’s) of highly doped, micromachined, periodic structures on silicon were measured...

Saturday, January 5, 2008

Polarized spectral emittance from periodic micromachined surfaces. I. Doped silicon: The normal direction

Peter J. Hesketh, Jay N. Zemel & Benjamin Gebhart ; Physical Review B.37.10795
VOLUME 37, NUMBER 18 1988


From the Abstract: The normal, polarized spectral (3 um <=lambda =>14um) emittances of highly doped, micromachined, periodic structures on heavily phosphorus-doped (110) silicon ([P]?5×1019cm-3) were measured for .....

Wednesday, November 21, 2007

Traceable emissivity measurements in RTP using room temperature reflectometry

By: Hunter, A.; Adams, B.; Ramanujam, R.
Advanced Thermal Processing of Semiconductors, 2003. RTP 2003. 11th IEEE International Conference on RTP
Volume , Issue , 23-26 Sept. 2003 Page(s): 85 - 88
Digital Object Identifier 10.1109/RTP.2003.1249127
Summary:

The design of an integrating reflectometer specific to the optical and spectral requirements of rapid thermal processing (RTP) is discussed. We report reflectance measurements of various materials. These measurements are correlated to in-situ emittance measurements recorded during rapid thermal processing. We also present the design of an optimized emissometer for an RTP chamber. We propose a means for correlating room temperature reflectance measurements to emittance standards for RTP.

View citation and abstract

Tuesday, August 21, 2007

Modeling and Simulation of Emissivity of Silicon-Related Materials and Structures

by N.M. RAVINDRA,(1,5) KRSHNA RAVINDRA,(1,2) SUNDARESH MAHENDRA,(1,3) BHUSHAN SOPORI,(4) and ANTHONY T. FIORY(1)
1.—Department of Physics, New Jersey Institute of Technology, Newark, NJ 07102. 2.—Intern atNJIT from Union County Magnet High School, Scotch Plains, NJ 07076. 3.—Intern at NJIT fromMillburn High School, Millburn, NJ 07041. 4.—National Renewable Energy Laboratory, Golden, CO 80401. Journal of ELECTRONIC MATERIALS, Vol. 32, No. 10, 2003, (Downloadable PDF Format)

Abstract:
"A brief review of the models that have been proposed in the literature to simulate the emissivity of silicon-related materials and structures is presented. The models discussed in this paper include ray tracing, numerical, phenomenological, and semi-quantitative approaches. A semi-empirical model, known as Multi-Rad, based on the matrix method of multilayers is used to evaluate the reflectance, transmittance, and emittance for Si, SiO2/Si, Si3N4/SiO2/Si/SiO2/Si3N4(Hotliner), and separation by implantation of oxygen (SIMOX) wafers. The influence of doping concentration and dopant type as well as the effect of the angle of incidence on the radiative properties of silicon is examined. The results of these simulations lead to the following conclusions: (1) at least within the limitations of the Multi-Rad model, near the absorption edge, the radiative properties of Si are not affected significantly by the angle of incidence unless the angle is very steep; (2) at low temperatures, the emissivity of silicon shows complex structure as a function of wavelength; (3) for SiO2/Si, changes in emissivity are dominated by substrate effects; (4) Hotliner has peak transmittance at 1.25 ?m, and its emissivity is almost temperature independent; and (5) SIMOX exhibits significant changes in emissivity in the wavelength range of 1–20 um."

"SPECTRAL EMISSIVITY OF HIGHLY DOPED SILICON"

by Curt H. Liebert and Ralph D. Thomas, NASA Lewis Research Center (Downloadable PDF File), APRIL 1968.

SUMMARY
"Measurements were made at temperatures of 300°, 882', and 1074' K of the normal was doped with a r s e n i c spectral emissivity of opaque, highly doped silicon. The silicon and boron to electron carrier concentrations of 2. 2X101', 3. %lo1', and 8 . 5 ~ 1 0 ~ ' electrons per cubic centimeter and hole carrier concentrationsof 6. 2X101' and 1 . 4 ~ 1 0 holes per cubic centimeter. The 30 K emissivity data were obtained at wavelengths from 2.5 to 35 microns. The high temperature emissivities were measured from 3.5 to 1 4 . 8 microns. Carrier concentrations and direct-current resistivity of the silicon were also measured. The carrier concentrations were determined from Hall measurements made at 30 K. The direct-current resistivity was measured at temperatures from 30 to 1200' K. These quantities (among others) were used in analytical calculations of the emissivities. Agreement of the Hagan-Rubens theory with experiment was found at wavelengths greater than 12 microns and at 30 K. Good agreement of the free carrier absorption theory with experiment w a s achieved at all wavelengths and temperatures investigated. The free carrier absorption theory predicts the emissivity in terms of the index of of these quantities are presented. A refraction and the absorption index. The values comparison of the values of the absorption index obtained herein with those obtained from the literature showed good qualitative agreement."

"Emissivity of silicon at elevated temperatures"

By P. J. Timans , Microelectronics Research Centre, Cavendish Laboratory, Cambridge University, Madingley Road, Cambridge CB3 0HE, United Kingdom Journal of Applied Physics -- November 15, 1993 -- Volume 74, Issue 10, pp. 6353-6364

Increasing the accuracy of your temperature measurements.

Monitor Newsletter at Windmill Software ( https://www.windmill.co.uk/ ) regularly publishes useful articles related to measurement, control,...